Bulletin of Stomatology and Maxillofacial Surgery
ISSN 1829-006X
2025; 392–400
Shared with The Gufo

MAINTENANCE REQUIREMENTS OF PEEK-COMPOSITE VERSUS METAL-CERAMIC TOOTHIMPLANT SUPPORTED RESTORATIONS: (A RANDOMIZED CONTROLLED CLINICAL TRIAL)

Received: 2026-04-08 · Published: 2025-07-27

Shared article.
Original title
MAINTENANCE REQUIREMENTS OF PEEK-COMPOSITE VERSUS METAL-CERAMIC TOOTHIMPLANT SUPPORTED RESTORATIONS: (A RANDOMIZED CONTROLLED CLINICAL TRIAL)
Author
Wael Abdulraziq Mohamed
Source journal
Bulletin of Stomatology and Maxillofacial Surgery
Published
2025-07-27
Licence
Creative Commons Attribution-NonCommercial 4.0 International
Original
https://doi.org/10.58240/1829006X-2025.21.6-392

Abstract

Background: Connecting teeth to implants was always associated with technical complications like veneer fracture and cement bond breakage, especially if rigidly connected, and intrusion with non rigid connection. Different materials were used with the gold standard treatment, porcelain fused to metal (PFM), showing the least technical complications of them. The search for less maintenance requiring material is still demanded. Aim: The aim of this study is to compare the maintenance requirements of polyetheretherketone (PEEK)-composite versus metal-ceramic tooth-implant supported prostheses (TISP). Materials and methods: This is a randomized, controlled clinical trial with a split mouth design. The trial included 12 patients (24 subjects). Patients with symmetrical Kennedy class I received one implant in the molar region, followed by a three unit fixed partial denture (FPD) connecting one molar implant to one premolar natural tooth on each side. In each patient, one side was restored with composite veneered to PEEK FPD, while the other side was restored with PFM FPD. The patients were recalled on 6, 12 and 18 month for inspection. The occurrence of technical complications or lack of was recorded, tabulated and statistically analyzed using Chi square test and Fischer exact test. Results: The result of the analysis showed that there is no statistical significant difference between the two groups regarding veneering material fracture, loss of cementation, and screw loosening/fracture. Conclusion: In Kennedy class I cases restored with tooth-implant-supported prosthesis (TISP), both metal-ceramic and PEEK-composite are viable FPD options in short follow-up period of 18 months. Neither of the aforementioned materials showed superiority in reducing prosthetic complications in TISP cases. A protocol of this study has a trial registration number of PACTR201504001079167.
1 / ? 100% Open in new tab Download Cite

Loading the full text…

Download Follow Updates