Communications Physics
ISSN 2399-3650
2026
Shared — curated by The Gufo editorial team
Real-time dual-telescope normalization for improved density estimation in absorption muography
Hamid Basiri*, Jun Matsushima, Masashi Kodama, Toshiyuki Yokota, Mohammed Y. Ali, Fateh Bouchaala, Ahmed Eleslambouly, Hiroyuki K. M. Tanaka, Eduardo Cortina, ANDREA GIAMMANCO
The University of Tokyo · Geological Survey of Japan; National Institute of Advanced Industrial Science and Technology; The University of Tokyo · Geological Survey of Japan; National Institute of Advanced Industrial Science and Technology · Khalifa University of Science and Technology · Earthquake Research Institute, University of Tokyo; The University of Tokyo · UCLouvain
Received: 2026-11-26 · Published: 2026-11-02
© 2026 The Author(s) and the original publisher.
Curated by The Gufo editorial team.
Originally published in Communications Physics, 2026 — https://doi.org/10.1038/s42005-026-02921-z.
- Original title
- Real-time dual-telescope normalization for improved density estimation in absorption muography
- Authors
- Hamid Basiri, Jun Matsushima, Masashi Kodama, Toshiyuki Yokota, Mohammed Y. Ali, Fateh Bouchaala, Ahmed Eleslambouly, Hiroyuki K. M. Tanaka, Eduardo Cortina, ANDREA GIAMMANCO
- Source journal
- Communications Physics
- Published
- 2026-11-02
- Licence
- Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
- Original
- https://doi.org/10.1038/s42005-026-02921-z
Authors and publishers can request removal at any time via Copyright infringement; we act within 48 hours.
Abstract
Absorption muography infers path-averaged density from the attenuation of atmospheric muons. Transient flux variations driven by weather, solar activity, and geomagnetism bias sequential measurements that rely on a non-simultaneous background. Here we show a real-time dual-telescope normalization in which two identical plastic-scintillator telescopes operate in parallel, one viewing open sky as a reference and one viewing the target. Their count-rate ratio cancels common-mode flux changes and tracks detector drift. A 140-h no-target run yields a stable calibration, and stacked acrylic slabs give an empirical transmission–thickness curve. Applied to blind targets, the dual-telescope workflow recovers the densities of 20-cm aluminum and 10-cm stainless-steel blocks within uncertainties, whereas a single-telescope workflow shows systematic biases of +18.95% and −22.82%. A vertical stack of the two telescopes further improves common-mode rejection, reducing calibration ratio scatter from 7.6% to 3.3%. The method is model-independent, removes systematic density biases in any campaign where a simultaneous flux reference is feasible, and is directly applicable to field deployments.