Nuclear Fusion
ISSN 0029-5515
2026
Shared — curated by The Gufo editorial team
Thermal management and net-power evaluation of the ST-E1 fusion power plant
Mohamed Khalid Elsharif Mohamed*, Alasdair Burchill, Liviu Maatescu, Emre Yildirim, Jonathan Naish, Matthew Robinson, Vandeep Godhani, Samara Levine, Sandeep Irukuvarghula, Chris Wilson, Ivan Krastev, Robin Kamenicky, Abhishek Kumar
Tokamak Energy Ltd
Received: 2026-11-01 · Published: 2026-07-10
© 2026 The Author(s) and the original publisher.
Curated by The Gufo editorial team.
Originally published in Nuclear Fusion, 2026 — https://doi.org/10.1088/1741-4326/ae5546.
- Original title
- Thermal management and net-power evaluation of the ST-E1 fusion power plant
- Authors
- Mohamed Khalid Elsharif Mohamed, Alasdair Burchill, Liviu Maatescu, Emre Yildirim, Jonathan Naish, Matthew Robinson, Vandeep Godhani, Samara Levine, Sandeep Irukuvarghula, Chris Wilson, Ivan Krastev, Robin Kamenicky, Abhishek Kumar
- Source journal
- Nuclear Fusion
- Published
- 2026-07-10
- Licence
- Creative Commons Attribution 4.0 International
- Original
- https://doi.org/10.1088/1741-4326/ae5546
Authors and publishers can request removal at any time via Copyright infringement; we act within 48 hours.
Abstract
Abstract A comprehensive analysis of the thermal management and net-power performance is presented for the ST-E1 low aspect ratio tokamak fusion power plant. The study addresses the critical interplay between coolant system design, power cycle integration, and electrical loads, which significantly influence net-power projections and overall plant viability. Specifically, it quantifies the impact of coolant loop design, pressure drops, pumping power, and thermal storage on plant efficiency, and examines the conditions required to achieve the pilot-phase net power target of 300–500 MWe. The findings provide insight into the system-level trade-offs that govern fusion plant viability and inform pathways toward improved net-power performance.
Summary
This paper examines the thermal management and net-power performance of the ST-E1 design, a low aspect ratio tokamak fusion power plant intended to serve as a pilot-scale demonstration of net electricity production. The authors focus on how the design of coolant loops, pressure drops, pumping power requirements, and thermal storage systems interact with the power cycle to determine how much net electricity the plant can actually deliver after accounting for internal power needs.
The study evaluates the system-level trade-offs involved in achieving the plant's target net power output of 300–500 MWe during its pilot phase. By quantifying the effects of coolant system design choices and associated electrical loads, the paper identifies the conditions necessary for the plant to meet its performance goals and outlines pathways for improving net-power output in future fusion power plant designs.
Plain-language summary by The Gufo; the paper is the authors’ own text.
Key findings
- The design of coolant loops, including pressure drops and pumping power requirements, has a significant impact on the net electrical output of the ST-E1 fusion power plant.
- Achieving the pilot-phase net power target of 300–500 MWe depends on careful integration of the coolant system with the power cycle and management of internal electrical loads.
- Thermal storage is identified as a relevant factor influencing overall plant efficiency and net-power performance.
- System-level trade-offs among coolant design, power cycle integration, and electrical loads are central to determining the overall viability of the fusion power plant.